DT-1000 Radiation Electromagnetic Detector Measuring Range 5-1999 Electromagnetic Field Intensity Detector
Rated 3.5/5 based on 11 customer reviews

DT-1000 Radiation Electromagnetic Detector Measuring Range 5-1999 Electromagnetic Field Intensity Detector

Image
:
R 901.60

1. Dimensions: 132×69×31mm
2. Weight: 200 grams
3. Reading display: 3-1/2 digit LCD
4. Gear position: electric field-V/m (volt/meter); magnetic field--uT (micro Tesla)
5. Accuracy: electric field: 1V/m; magnetic field: 0.01μT
6. Range: electric field: 1V/m-1999V/m; magnetic field: 0.01uT--19.99uT
7. Alarm threshold: electric field: 40V/m; magnetic field: 0.4uT
8. Test bandwidth: 5Hz-3500MHz
9. Sampling time: about 0.4 seconds
10. Sensor head: single axis (top of instrument)
11. Overload prompt: LCD displays "1"
12. Operating temperature: -15℃-+60℃
13. Operating humidity: relative humidity below 80%
14. Working voltage: 9V (6F22 9V battery) (not included)


Application range:
1. Outdoor environment electromagnetic radiation test application: all electromagnetic radiation sources within the instrument test technical indicators, such as substations, high-voltage lines, transformers, power distribution rooms, cables, mobile phone towers, TV signal towers, broadcast signal towers, etc.
2. Indoor environment electromagnetic radiation test application: computers, televisions, copiers, fax machines, air conditioners, refrigerators, stereos, washing machines, wires, power supplies, mobile phones, wireless routers, etc. All electromagnetic radiation sources within the instrument test technical indicators

1. Dimensions: 132×69×31mm
2. Weight: 200 grams
3. Reading display: 3-1/2 digit LCD
4. Gear position: electric field-V/m (volt/meter); magnetic field--uT (micro Tesla)
5. Accuracy: electric field: 1V/m; magnetic field: 0.01μT
6. Range: electric field: 1V/m-1999V/m; magnetic field: 0.01uT--19.99uT
7. Alarm threshold: electric field: 40V/m; magnetic field: 0.4uT
8. Test bandwidth: 5Hz-3500MHz
9. Sampling time: about 0.4 seconds
10. Sensor head: single axis (top of instrument)
11. Overload prompt: LCD displays "1"
12. Operating temperature: -15℃-+60℃
13. Operating humidity: relative humidity below 80%
14. Working voltage: 9V (6F22 9V battery) (not included)


Application range:
1. Outdoor environment electromagnetic radiation test application: all electromagnetic radiation sources within the instrument test technical indicators, such as substations, high-voltage lines, transformers, power distribution rooms, cables, mobile phone towers, TV signal towers, broadcast signal towers, etc.
2. Indoor environment electromagnetic radiation test application: computers, televisions, copiers, fax machines, air conditioners, refrigerators, stereos, washing machines, wires, power supplies, mobile phones, wireless routers, etc. All electromagnetic radiation sources within the instrument test technical indicators