Hantek 1008C 8CH USB Auto Scope/DAQ/8CH Programmable Generator
Rated 3.5/5 based on 11 customer reviews

Hantek 1008C 8CH USB Auto Scope/DAQ/8CH Programmable Generator

Image
:
R 3,940.93
1) Description:

- Cost-effective 8 channels oscilloscope for vehicle testing; 2.4MSa/s, 12bits; DAQ card function; 8 channels programmable generator which can analog signals of crankshaft, camshaft etc.

- Vehicle Testing

- First Diagnosis: Intake manifold vacuum & ignition, Petrol fumes adjusting valve vacuum & ignition, Idle exhaust ignition, Starting exhaust ignition

- Ignition: primary and secondary

- Sensor: Air Flow Meter, Camshaft, Crankshaft, Distributor, Lambda sensor, Throttle position

- Bus Diagnosis: CAN bus data examine, CAN bus signal integrity, CAN bus LH long time acquisition, LIN bus

- Performer: Petrol/Diesel

- Starter and charging circuits

2) Oscilloscope

- 8 channels oscilloscope, 2.4MSa/s real time sampling rate

- 12 bits vertical resolution, spectrum analysis function

Programmable Generator

- 8 channels programmable generator

- Can analog signals of crankshaft, camshaft etc.

3) Others

- USB 2.0 interface plug and play, and no need extra power supply;

- More than 20 types of automatic testing function, a similar interface with benchtop oscilloscope, easy to use;

- Software support: Windows NT, Window 2000, Windows XP, VISTA, Windows 7;

4) Software Support

- Operating System: Windows NT, Windows 2000, Windows XP, VISTA, Windows 7

5) Specification:

- Model Hantek1008C

- Oscilloscope Mode

- Vertical Analog Channel 8

- Input Impedance Resistance: 1M?

- Input Sensitivity 10mV/div to 5V/div

- Input Coupling DC

- Resolution 12 bits

- Horizontal Memory Depth 4K

- Max. Input 400V (DC+AC Peak)

- Real-Time Sampling Rate 2.4MSa/s

- Time Base Range 1ns/div to 20000s/div(1-2-5 sequences)

- Time Base Precision ±50ppm

- Trigger Source CH1, CH2,CH3,CH4, CH5, CH6,CH7,CH8

- X-Y Mode X-Axis Input CH1

- Y-Axis Input CH2

- Cursors and Measurement Voltage Measurement Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase,Vavg, Vrms, Vcrms, Preshoot, Overshoot

- Time Measurement Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width,

- Cursors Measurement Horizontal ,Vertical, Track, Auto Measure Modes

- Waveform Signal Process: +,- , x,÷, FFT, Invert

- Voltage Range: 10mV to 5V/div @ x 1 probe

- 100mV to 50V/div @ x 10 probe

- 10V to 5000V/div @ x 1000 probe

- 100V to 50000V/div @ x 10000 probe

- 200mV to 100V/div @ 20:1

- Current Range: 100mA to 50.0A/div @ CC65(20A)

- 1000mA to 500.0A/div @ CC65(65A)

- 1A to 100.0A/div @ CC650(60A)

- 10A to 1000.0A/div @ CC650(650A)

- 1A to 200.0A/div @CC1100(100A)

- 10A to 2000.0A/div @CC1100(1100A)

- Cursor: Time/frequency difference, voltage difference

- FFT: Rectangular, Hanning, Hamming, Blackman Window

- Math: Addition, subtraction, multiplication, division

- Channel: 8

- Output Level: LVTTL

- Frequency Range: 0-250kHz

- Interface: USB 2.0

- Power : No need extra power supply

- Measurement Size 185 x 150 x 27 (mm)

- Weight 0.35
1) Description:

- Cost-effective 8 channels oscilloscope for vehicle testing; 2.4MSa/s, 12bits; DAQ card function; 8 channels programmable generator which can analog signals of crankshaft, camshaft etc.

- Vehicle Testing

- First Diagnosis: Intake manifold vacuum & ignition, Petrol fumes adjusting valve vacuum & ignition, Idle exhaust ignition, Starting exhaust ignition

- Ignition: primary and secondary

- Sensor: Air Flow Meter, Camshaft, Crankshaft, Distributor, Lambda sensor, Throttle position

- Bus Diagnosis: CAN bus data examine, CAN bus signal integrity, CAN bus LH long time acquisition, LIN bus

- Performer: Petrol/Diesel

- Starter and charging circuits

2) Oscilloscope

- 8 channels oscilloscope, 2.4MSa/s real time sampling rate

- 12 bits vertical resolution, spectrum analysis function

Programmable Generator

- 8 channels programmable generator

- Can analog signals of crankshaft, camshaft etc.

3) Others

- USB 2.0 interface plug and play, and no need extra power supply;

- More than 20 types of automatic testing function, a similar interface with benchtop oscilloscope, easy to use;

- Software support: Windows NT, Window 2000, Windows XP, VISTA, Windows 7;

4) Software Support

- Operating System: Windows NT, Windows 2000, Windows XP, VISTA, Windows 7

5) Specification:

- Model Hantek1008C

- Oscilloscope Mode

- Vertical Analog Channel 8

- Input Impedance Resistance: 1M?

- Input Sensitivity 10mV/div to 5V/div

- Input Coupling DC

- Resolution 12 bits

- Horizontal Memory Depth 4K

- Max. Input 400V (DC+AC Peak)

- Real-Time Sampling Rate 2.4MSa/s

- Time Base Range 1ns/div to 20000s/div(1-2-5 sequences)

- Time Base Precision ±50ppm

- Trigger Source CH1, CH2,CH3,CH4, CH5, CH6,CH7,CH8

- X-Y Mode X-Axis Input CH1

- Y-Axis Input CH2

- Cursors and Measurement Voltage Measurement Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase,Vavg, Vrms, Vcrms, Preshoot, Overshoot

- Time Measurement Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width,

- Cursors Measurement Horizontal ,Vertical, Track, Auto Measure Modes

- Waveform Signal Process: +,- , x,÷, FFT, Invert

- Voltage Range: 10mV to 5V/div @ x 1 probe

- 100mV to 50V/div @ x 10 probe

- 10V to 5000V/div @ x 1000 probe

- 100V to 50000V/div @ x 10000 probe

- 200mV to 100V/div @ 20:1

- Current Range: 100mA to 50.0A/div @ CC65(20A)

- 1000mA to 500.0A/div @ CC65(65A)

- 1A to 100.0A/div @ CC650(60A)

- 10A to 1000.0A/div @ CC650(650A)

- 1A to 200.0A/div @CC1100(100A)

- 10A to 2000.0A/div @CC1100(1100A)

- Cursor: Time/frequency difference, voltage difference

- FFT: Rectangular, Hanning, Hamming, Blackman Window

- Math: Addition, subtraction, multiplication, division

- Channel: 8

- Output Level: LVTTL

- Frequency Range: 0-250kHz

- Interface: USB 2.0

- Power : No need extra power supply

- Measurement Size 185 x 150 x 27 (mm)

- Weight 0.35